• Skip to main content
  • Skip to header right navigation
  • Skip to after header navigation
  • Skip to site footer
NAFA Logo

National Air Filtration Association

  • Home
  • Member Login
  • COVID-19
  • Webinars
  • About
    • NAFA Executive Officers
    • NAFA Board of Directors
    • NAFA Past Presidents
    • NAFA Committees
    • NAFA Staff
  • Events
    • Calendar
    • Get the 2022 Sponsorship Prospectus!
    • 2022 Annual Convention
    • AHR Expo 2023
    • Call for Air Filtration Topics
  • Certification
    • Certified Air Filter Specialist
    • Certified Technician Level I
    • Certified Technician Level II
    • NAFA Certified Individuals (nonmember)
  • Programs
    • Clean Air Award Program
    • Scholarship Program
      • NAFA Scholarship Recipients
    • Membership Awards
    • Ascent Global Logistics
      • Frequently Asked Questions on Freight Classification & NMFC Rules
  • Resources
    • Get the 2022 Sponsorship Prospectus!
    • Additional Resources
    • Advertising on the NAFA Website
    • Air Filtration Articles
    • Air Media Magazine
    • Download Best Practice Guidelines
    • Guide to Air Filtration
    • Guide to ISO 16890
    • IOM of Air Filtration Systems
    • Store
    • Understanding MERV
  • Foundation
  • Membership
    • Join
    • Code of Ethics
    • Distributor Members
    • Manufacturer Members
    • Service Provider/Allied Members
    • Professional & Student Members
    • Life Members
  • Contact
    • Add me to your email list!
    • Information Request

Aerosol Treatment Chambers

While the largest amount of filtration business in a healthcare facility is typically found within the air handling system, there are many unique applications where filtration is used as part of a diagnostic or medical treatment procedure. One of these applications is the aerosol treatment chamber.

An aerosol treatment chamber or booth is a negative pressure mini-environment that has HEPA filtered exhaust. The booth is maintained under negative pressure in order to prevent harmful airborne pathogens or treatment aerosols from being introduced into the facility. These booths are often provided with a pressure monitor that continually shows the pressure status of the booth and has an audible alarm to alert workers if the negative pressure is ever compromised.

A patient sits in the chamber during the administration of an aerosol used for diagnostic analysis or therapeutic treatment. The most common applications for aerosol treatment chambers are sputum induction procedures and aerosolized pentamidine treatments.

Pentamidine treatments:

Pentamidine Treatment administered in an Aerosol Treatment Chamber

Pentamidine is an aerosol that may be used in the treatment of immune compromised pneumonia patients. This aerosol though, may adversely affect the health of caregivers if there is repeated exposure over a pro-longed period of time. To reduce the risk to staff, these treatments are normally given to patients inside an aerosol treatment chamber or a negative pressure isolation room.

Sputum Induction: Sputum induction is typically performed on patients to confirm or rule out a diagnosis of active TB disease. It is used to obtain sputum for diagnostic purposes when patients are unable to spontaneously expectorate a specimen. The procedure uses sterile water or hypertonic saline to irritate the airway, increase secretions, promote coughing, and produce a specimen. The CDC and the Occupational Safety and Health Administration (OSHA) both classify sputum induction as a high-risk procedure when performed on a suspected or known infectious TB patient. This procedure induces coughing, resulting in a greater likelihood that infectious droplet nuclei are expelled into room air.1

Performing a sputum induction in an aerosol treatment chamber with HEPA filtered exhaust, instead of a negative pressure room may provide increased protection for the healthcare worker administering the test. This eliminates the need for the healthcare worker to wear a respirator during the procedure.2

Aerosol Treatment Chamber

The HEPA filtered exhaust from the booth or chamber may be discharged back into the room or exhausted to the outside.3 If the exhaust air is discharged into the room, a HEPA filter should be incorporated at the discharge duct or vent of the device. The exhaust fan should be located on the discharge side of the HEPA filter to ensure that the air pressure in the filter housing and booth is negative with respect to adjacent areas. Uncontaminated air from the room will flow into the booth through all openings, thus preventing infectious droplet nuclei in the booth from escaping into the room.4

The HEPA filters on these enclosures should have appropriate pre-filtration and should be changed when the enclosure is no longer able to maintain negative pressure or provide a minimum of 12 air changes per hour of HEPA filtered exhaust. When changing the filters the maintenance person should wear N-95 respirators and gloves.5 The filter should be handled gently and sealed into a plastic bag after removal. The CDC does not recommend red bagging of these filters, stating that disposal in normal trash 6 is appropriate. Local and state codes should be consulted though, as they may differ.

References:

1, 2, 3 Francis J. Curry National Tuberculosis Center, Institutional Consultation Services. Conducting Sputum Induction Safely. 1999.

4, 5 Guidelines for Preventing the Transmission of Mycobacterium tuberculosis in Health-Care Settings 2005 (Draft) Department of Health and Human Services, Centers for Disease Control and Prevention.

6 Guidelines for Environmental Infection Control in Health-Care Facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC) 2003.

Aerosol Treatment Chambers; Winter 2006 issue of Air Media
Author(s): Bill Palmer, AeroMed, Inc.

Sidebar

Contact Us

Call 608-310-7542 or email nafa@nafahq.org

Follow Us

Search by Tags

52.2 Testing Aerosol Airflow Allergens ASHRAE Best Practices Business Cannabis CDC Conference Contaminant COVID-19 Dust EPA Fan FAQ Guidelines Healthcare HEPA High Efficiency IAQ Infectious Diseases ISO MERV Odor Control Particles schools Sick Building Syndrome UV Ventilation VOC Wildfires

Social

Follow along on social media

  • Facebook
  • Twitter
  • LinkedIn
  • Spotify
  • YouTube

Contact

Get in touch with us here

608-310-7542

nafa@nafahq.org

Navigation

  • Home
  • About NAFA
  • Join NAFA
  • Contact NAFA

Copyright © 2022 · National Air Filtration Association (NAFA) · All Rights Reserved